ATR902 is a hand-held programmer specifically designed for automating small hobby or professional kilns often used in ceramics firing , glass fusing or goldsmithing.
ATR902 allows the programming of 15 cycles/curves with time-dependent temperature control. Each cycle can contain up to 18 steps/segments, all freely configurable by the user as up/down/down.
Cycle programming and visualisation are simple and intuitive, even for non-expert operators.
Typical furnace control software functions are provided: Delayed Start, End-of-Step Wait (in case of process delay at the programmed setpoint) and Cycle Recovery Mode (after any power failure).
The multi-pin connector, which is also compatible with the previous ATR900/901 series, allows the user to make an immediate connection/installation. The pin-out specifications are detailed in the documentation and allow manufacturers to correctly set up the corresponding connector on the oven.
The input is programmable for the most common thermocouples and there are two selectable outputs as control or alarm/auxiliary.
All options are configurable from the keypad (probe type, alarm mode, cycle programming).
- Dimensions120 x 65 (front panel) x 65 mm
- MaterialBox: PC UL94V2 self-extinguishing, Front panel: PC UL94V2
- WeightApprox. 550 g
- SealingFront panel: IP54, Box and terminal blocks: IP20
- Operating conditionsTemperature 0-45 °C, humidity 35..95 RH%
- CertificationsCE
ORDERING CODES | ATR902-12ABC |
---|---|
Power supply | 24..230 V AC / DC ±15% 50/60 Hz - galvanic isolation 2,5KV |
Power consumption | 3 Watt/VA |
Display | Display 4 digit 0,56" red + 4 digit 0,4" green + Bargraph |
Analogue inputs | 1 x Ris. 16bit, programmable for K, S, R, J ,T , E, N (automatic compensation of the cold junction 0..50°C, precision @25°C ±0,2% F.S. ±1 digit F.S.) |
Sampling time | Programmable up to 2,1 ms (frequency up to 470 Hz) |
Digital inputs | - |
Relais output | 2 x Relais 1A - 250VAC resistive load (with output signal from supply voltage) |
- Control algorithmsON - OFF with hysteresis, P., P.I., P.I.D., P.D. time proportional
- TuningManual, Automatic predictive
- Alarm modeAbsolute / Threshold, band, High / Low deviation, timed auxiliary programmable on single steps
- Software parameter configurationMemory Card, software LABSOFTVIEW, codes EASY-UP - Programming via APP (NFC) "MyPixsys" for Android and Ios devices
- Software protectionsLock of control / alarm setpoint / Access to parameters by password
- ATR902-12ABCPLUG-IN PROGRAMMER/TEMP. CONTR.15 CYCLES
- ACCESSORIES' CODES
- 0400.70.001KIT HARTING 8P ATR902